Top » Industrial Lavatories and Sinks » Restroom Partitions » Guidelines for Measuring Restroom Stall Dimensions for School Ba
| Cart Contents | Checkout

Subscribe to receive the latest news & specials on our products:
Quick Find
 
Use keywords to find the product you are looking for.
Advanced Search
Shopping Cart more
0 items
Categories
Bleachers & Industrial Warehouse->
Commercial Signage->
Commercial/Residential Mailboxes->
Industrial Lavatories & Sinks->
Lockers & Storage Units->
Outdoor Commercial Furniture->
View All Products
Articles
New Articles
All Topics
 Bleachers ->
 Commercial Mailboxes ->
 Commercial Signage
 Industrial Lavatories and Sinks ->
   Bradley Hand Wash Fountains
   Commercial Bathroom Lavatory Sys
   Commercial Bathroom Mirrors
   Commercial Faucets
   Commercial Restroom Partitions
   Commercial Shower Enclosures
   Commercial Washroom Accessories
   Electric Hand Dryers
   Emergency Eye Wash Stations ->
   Grab Bars
   Medical Plumbing Fixtures
   Restroom Dispensers
   Restroom Partitions
   Security Fixtures
   Security Washroom Accessories
   Shower Seats
   Urinals
   Waste Receptacles
 Lockers and Storage Units ->
 Outdoor Commercial Furniture ->
Articles RSS Feed
Information
Shipping & Returns
About Us
Contact Us
Catalog Feed
Reviews more
Dual Roll Recessed Toilet Tissue Dispenser
eka90C _a href="http-
://kaxfuytdtxpg-
.com/"_kax-
fuytdtxpg_/a_, ..

3 of 5 Stars!


Guidelines for Measuring Restroom Stall Dimensions for School Ba

Shop our Online Catalog: Industrial Lavatories & Sinks
Commercial Bathroom Lavatory Sys
Commercial Bathroom Lavatory Sys
Commercial Washroom Accessories
Commercial Washroom Accessories
Commercial Restroom Partitions
Commercial Restroom Partitions
Commercial & Industrial Faucets
Commercial & Industrial Faucets
Stainless Steel Service Sinks
Stainless Steel Service Sinks
Multi-Station Wash Fountains
Multi-Station Wash Fountains

Partitions - Baked Enamel - Floor Mount Overhead BracedXPB Locker can help you design your restroom layout when you are measuring restroom stall dimensions for school bathrooms.  Different layouts require different standards of measurements for the proper positioning of partitions, pilasters, door, toilets, and accessories in the right locations. 

 

We are always willing to assist contractors save time in working out these complex diagrams and developing a free design drawing with every toilet partition quote.  With a few basic measurements that must be taken from within the restroom itself by the contractor in the field, we can develop the specifics of both standard and ADA compliant stall units so that any necessary customization of hardware can be passed on to the manufacturer at the time of purchase.

 

Regardless of the layout or mounting style, the same basic conventions apply to all measurements.  Compartment width is determined either by the distance between two walls, the distance between a wall and a panel, or by the distance between two panels.  The distance between the front edge of the pilaster and the back wall determines compartment depth.  The opening size of the door is determined by the distance between two pilaster edges.  A standard 30 inches must be added to the door opening size to create an inswing for the door that will clear the front of the toilet.

 

Depending on how you mount your partitions, other factors will also come into play when measuring restroom stall dimensions for school bathrooms.  When configuring and overhead braced layout, it is necessary to have a ceiling that is at least 88 inches above the door so that the top of the head rail will measure 85 inches from the floor.

 

Ceiling hung or floor-to-ceiling mounted pilasters require measuring the distanceBathroom between the ceiling and the floor.  If you are dealing with a floor that slopes 1 inch or more, please measure the distance between the floor and ceiling in the places where you intend to mount pilasters.  We will note this in your free design drawing and make certain that your pilasters are manufactured at the right dimensions prior to shipment.

 

When configuring wall-to-wall layouts, it is very important to remember that the most critical measurement is the shortest point between the walls.  The position of the walls will in turn determine the locations of the panels and doors.  Measurements should be taken from the baseboard when determining pilaster locations.

 

More challenges will occur when contractors encounter wall treatments that create varying spaces between parts of the wall.  When measuring restroom stall dimensions in school bathrooms with cove moldings, windows, baseboard heaters, and windows, contractors should notify XPB Locker of these variations so we can develop the appropriate workaround and notate your free design drawing accordingly.

 

Toilet Partitions - Phenolic Core - Floor MountIn time sensitive projects, it is best to rely upon the help of others than can avert the possibility of costly design errors and design installation beyond project deadline.  XPB Locker Supply will offer consultative, interactive help to the fullest extent possible whenever architects, school facility managers, or contractors request it.

XPB Lockers & Supply carries a wide variety of Commercial Lavatories, Commercial Outdoor Furnishings, Storage Lockers, Bleachers,Commercial Mailboxes and deliver nationwide. If you can not find what you are looking for call us toll free at 1-877-483-9270 and we will find it for you. Our home office is located in New Braunfels, Texas with distributors located in all 50 States including Houston, TX, New York NY, Los Angeles CA, Miami, FL. Chicago, IL. Denver CO., Dallas TX, San Antonio, TX., and Austin, TX.

This article was published on Tuesday 15 May, 2012.



Back to main topic: Restroom Partitions
Current Reviews: 0
Write Review
 
| Lockers & Storage Units | Industrial Lavatories & Sinks | Commercial Bathroom Supply | Outdoor Commercial Furniture |
| Commercial Signage | Bleachers | Commercial Mailboxes
| Blog Archive | Blog | Contact Us

XPB Locker & Supply
New Braunfels, TX 78132
1-877-483-9270